Security model
/config grants direct loopback clients local administration without an API token, including access to credentials and privileged settings. All local users who can reach the listener must be trusted. The page and Blazor transport reject remote peers, non-local Hosts, forwarded headers and cross-origin requests. Never proxy /config, /_blazor, /_framework or /_content: a proxy hiding its origin can bypass the loopback trust boundary. The one exception is MudBlazor CSS and fonts under /_content/MudBlazor/ (GET and HEAD, never .js), which are reachable off loopback so the one-time /system/logon/consent/{id} page can load its styles. Saving validates settings; applying them requires a restart that interrupts jobs and connections.
Vestigo is meant to give an agent administrator-equivalent reach on a lab PC. The defaults try to keep that reach local, token-gated, and off until you ask for it. This page is the booklet summary, not the full policy.
Tokens
- A fresh MSI install binds every interface and writes a generated bearer token into
%ProgramData%\Nefarius Software Solutions\Vestigo\appsettings.json. dotnet rundefaults to loopback with no tokens.- When
ApiTokensis non-empty,/mcprequiresAuthorization: Bearer <token>, while/filesaccepts that bearer token or a valid one-time ticket. Tokens are compared by SHA-256 digest and are never written to logs. /and/healthstay anonymous.- Binding beyond loopback without tokens is allowed and logs a startup
SECURITY WARNING. Use that only on a network you trust. - An MSI upgrade or repair keeps the saved tokens, listen address and port, even from an unelevated wizard that cannot read the protected settings file, and reconciles the inbound firewall rule
Vestigo MCP Server(removed for loopback and on uninstall). It also provisions the protected ProgramData tree, includingspool\helper, and refuses to proceed over a link, plain file, or a directory holding anything but Vestigo scratch files.
Roots
- Trace ETL, PDB, TMF, and conversion-output paths stay inside
AllowedInputRootsorAllowedOutputRoots(default: the protectedtracesfolder). - File, log, process, and device paths use named
Vestigo:Roots(and optionalVolumeRoots) withRead,Write, andExecute. - A root, or a directory containing a root, cannot be deleted or moved. NTFS stream syntax is rejected.
- Write or Execute on a whole volume is a privilege boundary: a client can replace drivers, services, and scripts.
Modules that stay off
Power is on by default and read-only. It discloses AC status, battery charge, the active scheme name, sleep-policy settings, and the newest Power-Troubleshooter wake text, which can name a timer owner. It does not list power-request owners or change the scheme. System is on by default. get_boot_state discloses uptime, an approximate boot time, whether Fast Startup is configured, safe mode, and how many file renames are pending. It does not disclose the queued paths. list_logon_sessions and get_logon_session disclose who is logged on and which session is the console. Client names and addresses are omitted unless includeClientAddresses is true, and they are not written to the log. There is no logoff or session-connect tool.
These stay disabled until you enable the module: Processes, Devices, RemoteDebugger, Desktop, Input, Audio, DebugOutput, Diagnostics, Performance, Registry, and WindowsServicing. Processes, RemoteDebugger, Diagnostics, Performance, and WindowsServicing also need Jobs, RemoteDebugger needs Processes as well, and Input needs Desktop. Software, which is on by default, needs Jobs. Registry does not. Services and Environment, including their mutating tools, are on by default and have no separate gate. With Registry on, clients can read values under the allowed prefixes, and Winlogon stays denied. A symbolic link is followed only when its target also passes those checks. With Devices on, inspect_hid_device can return manufacturer, product, and serial strings. It does not read input reports. Enabling the powerful ones without tokens is allowed and logs a startup warning. With Diagnostics on, that warning also names process and machine-wide connections, TCP connection statistics, routing, DNS, and proxy configuration, Media Foundation encoders and camera formats, audio format checks, Windows Error Reporting metadata, Driver Verifier state, driver load evidence, and kernel dump file names. Online Authenticode revocation (Diagnostics:AllowOnlineRevocation), capture probes (Diagnostics:AllowCaptureProbes), network probes (Diagnostics:AllowNetworkProbes), audible audio probes (Diagnostics:AllowAudioPlayback), process dumps (Diagnostics:AllowProcessDumps), firewall inventory (Diagnostics:AllowFirewallInventory), Driver Verifier changes (Diagnostics:AllowDriverVerifier), and kernel dump staging (Diagnostics:AllowKernelDumpStaging) stay off even after Diagnostics is enabled. A UDP probe sends one datagram and can return an unauthenticated STUN reflexive address. Silence is not reported as a firewall block. Network probes also require Diagnostics:AllowedProbeDestinations. SetupAPI install history reads only the fixed system logs and does not rank drivers. Capture probes report frame arrival only and do not return pixels. The direct probe connection contacts only the destination listed in Diagnostics:AllowedProbeDestinations and does not capture packets. TLS chain building may also contact Authority Information Access issuer servers, and online revocation may contact revocation servers when Diagnostics:AllowOnlineRevocation is true. AllowedProbeDestinations does not limit those extra contacts. Crash reports are metadata only. Process dumps are not uploaded.
Separate gates
Even after a module is on, these actions stay off until their own setting is true:
Software:AllowUninstallScheduledTasks:AllowChangesDesktop:AllowScreenshotsDesktop:AllowWindowPlacementDesktop:AllowDisplayLayoutChangesDesktop:AllowDesktopSessionsInput:AllowInputAudio:AllowSetDefaultSystem:AllowBootConfigurationChangesSystem:AllowUacChangesSystem:AllowRebootSystem:AllowAutoLogonChangesSystem:AllowInteractiveLogonUpdates:AllowSelfUpdateDiagnostics:AllowOnlineRevocationDiagnostics:AllowCaptureProbesDiagnostics:AllowNetworkProbes(also needsDiagnostics:AllowedProbeDestinations)Diagnostics:AllowAudioPlaybackDiagnostics:AllowProcessDumpsDiagnostics:AllowDriverVerifierDiagnostics:AllowFirewallInventoryDiagnostics:AllowKernelDumpStagingPerformance:AllowKernelTracePerformance:AllowRawEtlCapturePerformance:AllowStorageProbesPerformance:AllowPacketDropCapture
Attaching to someone else’s ETW session stays off until you list the session name in AttachableSessions. observe_presentation starts and stops only its own short Vestigo- session, and decodes it outside the service process.
Screen and input
Screenshots, inspect_screen, and find_on_screen can disclose whatever is on the console user’s screen. UI Automation names and OCR text come back as plain text, which is easier to copy out than pixels. Edit-control values are not read through UI Automation. Text that is visible can still be read by OCR.
send_input acts as the console user. Anything on screen can be clicked or typed into. With elevated: true, that input is administrator-equivalent while an elevated window is open. The helper sends input only while the input desktop is the session’s default desktop. That blocks the lock screen, Ctrl+Alt+Del, and a UAC prompt drawn on the secure desktop. When secure-desktop prompting is off, the UAC prompt stays on the interactive desktop and this check allows the input. The action batch is base64 JSON on the session helper command line. With command-line auditing enabled, event 4688 can record that argument, including typed text. Do not type secrets through send_input on a machine that audits process creation.
requireFocus refuses a batch unless the chosen window is foreground before each submission, but Windows can still change focus before SendInput runs and a click lands on the window under the pointer. When a batch stops, only the keys and buttons that batch holds are released; ones the user is holding are left alone. Calls on one input desktop run one at a time. inputMode: keys translates each text action when it starts, so earlier actions in the same call may already have been sent. injection.timing records times only, never typed text.
Managed test desktops (Desktop:AllowDesktopSessions) can switch the console user’s input desktop. Vestigo assigns the Vestigo- desktop name, refuses the lock screen and UAC, and restores the recorded input desktop on close or restart.
The MSI preserves hand-set Desktop:AllowScreenshots, Desktop:AllowWindowPlacement, Desktop:AllowDisplayLayoutChanges, Desktop:AllowDesktopSessions, Input:AllowInput, System:AllowReboot, System:AllowAutoLogonChanges and System:AllowInteractiveLogon on an unelevated upgrade when the matching feature stays unselected.
Reboot, AutoLogon, and interactive logon
reboot_machine restarts this machine only. An immediate restart drops every MCP client, and force closes other sessions without prompting, so unsaved work is lost. cancel_reboot aborts a countdown.
None of these tools take the password as an argument. A person types it on a one-time /system/logon/consent/{id} page, so open that URL in a user-facing desktop browser, never a headless, embedded or IDE browser. For AutoLogon the password is stored as an LSA secret. For sign-in and unlock it goes only to LogonUI over a SYSTEM-only named pipe. It is never logged or written to appsettings.json. lock_workstation needs only System:AllowInteractiveLogon. request_interactive_logon and request_unlock_workstation also need the Credential Provider, which the Server feature stages and the MSI Interactive logon feature registers.
Windows servicing data
WindowsServicing is opt-in and requires Jobs. Enabling it without API tokens logs a warning about the data it exposes. Update history, package identities, service/process names, Windows-volume space and fixed-file metadata can identify software or users on the machine. Raw pending-file queue paths are returned even outside configured roots; queue inspection never opens those files.
CBS/DISM log content and caller-selected file-locker queries require Read roots. WindowsServicing adds no roots of its own; existing roots apply, including the fresh MSI default FixedVolumes roots. Logs can contain sensitive machine/user data. Failure evidence is bounded, and an unavailable source remains unknown or an explicit error. Empty results are not proof that servicing is healthy.
WUA inventory is offline-only, but can perform substantial local work and write its own cache/log data. DISM enumeration can write diagnostic logs. Neither tool installs updates or repairs Windows. No queue editing, cache reset, process shutdown or system reboot is exposed. Native calls share one slot; timeout or cancellation stops waiting and retains that slot until Windows returns.
Plain HTTP
Traffic is not TLS. Tokens, tickets, traces, screenshots, and Windows passwords typed on the logon consent page cross the network in the clear unless a TLS-terminating proxy is in front. The consent page warns on plain HTTP from a non-loopback client and still accepts the form. Use a trusted network or a TLS-terminating proxy when the server is reachable beyond the machine. One-time /files tickets expire, bind to one path, and are consumed on first use; treat the URL as a secret until then. A take_screenshot share URL is the same kind of secret for a downscaled preview: it lasts 10 minutes, works once, and does not require the API token.
Trusted plugins
Plugin loading is disabled by default. Plugins execute with the service’s privileges; assembly dependency isolation is not a security sandbox. Deployment ACLs, reparse checks and optional complete-package SHA-256 pins protect installation. Every token holder can use every enabled plugin tool. Anonymous plugin endpoints are rejected. Administrator-equivalent tools remain administrator access and can bypass file path guards. See the full plugin trust model.
API 1.1 session-required providers fail closed unless a valid bearer credential and explicit application session ID are present. Their isolation key combines the host’s opaque owner ID with the selected session ID. Sharing both values shares a key. This is not a transport session, permission scope or sandbox; providers must enforce resource ownership and cleanup. See session identity.
Back to the intro, features, developers, or QA.